Abstract
In the course of scientific collaboration, we were involved in discussion on the capacity of a vertical loop configuration to resolve thin high-resistivity layers, which is quite an interesting and largely debated point. We report a small forward modeling study including an algorithm based on an analytical solution by separation of variables and a respective program for computing the time-domain TEM field of a horizontal magnetic dipole. We infer that the subsurface vertical loop system shows no critical advantage in resolving thin insulating inclusions.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.