Abstract

Acoustic oscillations in nuclear steam supplies have caused structural vibration leading to plant modifications in both pressurized water reactor and boiling water reactor (BWR) systems. Power increases (i.e., uprates) in some BWR designs have resulted in acoustic oscillations in the steam supply that have caused fatigue failures in steam dryer assemblies. Standing waves in side branch lines are identified as one important acoustic source for waves in the main lines. The side branch standing waves are driven by vortex shedding across the branch opening. The side branch lines couple acoustically with standing waves in the main line, extending the range of physical behavior beyond that normally considered in the literature. There are many side branches mounted where there is flow in the main steam line, creating multiple acoustic sources, many of nearly the same frequency. These multiple sources cause time variation in the acoustic performance that may extend over many seconds, and these attributes must be considered during data acquisition, component load simulation, and stress simulation. Wet steam sound speed models appropriate to BWR steam supply conditions are also presented.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.