Abstract

The field of computer-assisted radiology and surgery involves a wide spectrum of topics based on medicine, physics, computer science and even sociology. The progress of development and recent trends in this field is described in this paper. Firstly, the chronological change in presented papers in past international conferences of Computer Assisted Radiology and Surgery (CARS) from 1985 to 2007 is illustrated in terms of topics, which are grouped into six main categories. Secondly, new directions and related topics are described by means of an example of a digital operating room. Problems in the operation room (OR) and solution concepts are pointed out while a therapy imaging and model management system (TIMMS) is presented as a possible solution. Finally, patient modelling related topics for CARS are listed.

Highlights

  • Intensity modulated radiotherapy (IMRT) utilises small beamlets of ionising radiation to provide a highKhamfongkhruea et al Biomed Imaging Interv J 2012; 8(1):e5This page number is not for citation purposes use a respiratory gating system

  • The measurements by MapCheck show the gamma index of the planned absolute dose distribution in static and moving targets with gating, resulting in more than 96% passing for all dose rates

  • The absolute dose distribution measured by film for the static target was agreeable with the value of moving target with gating

Read more

Summary

Introduction

Intensity modulated radiotherapy (IMRT) utilises small beamlets of ionising radiation to provide a highKhamfongkhruea et al Biomed Imaging Interv J 2012; 8(1):e5This page number is not for citation purposes use a respiratory gating system. Chen et al [5] studied the dosimetric effects caused by the respiratory motion during IMRT by using Kodak EDR2 films. They concluded that, without the gating system, the dose distribution of the stationary phantom was different from the moving one. Duan et al [7] studied the dosimetric effect of respiration-gated beam with IMRT delivery Their results suggested that low dose rate can reduce the effect of delay and catch-up cycle. Lin et al [2] determined the effect of radiation dose rate with moving target and the gated treatment using step-and-shoot IMRT delivery. The high dose rate gated stepand-shoot IMRT was dosimetrically accurate, shortened the delivery time, and was safe to use clinically

Objectives
Methods
Results
Conclusion
Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.