Abstract

This work is mainly based on the optimal design of a standalone Hybrid Renewable Energy System (HRES) consisting of PV/diesel/battery systems, implemented in an academic building. Different hybrid system configurations such as PV-diesel generator-battery, diesel generator-battery, and PV-diesel generator are compared based on Net Present Cost (NPC) and Cost Of Energy (COE) to find out the best economically viable and environmentally friendly solution. Li-ion and lead-acid batteries were taken into consideration, and the optimization was done in HOMER PRO software. The PV-DG-Li-ion battery configuration emits approximately 2825387kg/year CO2 whereas the conventional DG system emits 4565074kg/year. It is concluded that the PV-DG-Li-ion battery configuration provides the cleanest and most environment-friendly and techno-economically feasible solution.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.