Abstract
The mobilized thermal energy storage (M-TES) system is a promising alternative to conventional heating systems to meet the heat demand for distributed users. This paper provided a techno-economic assessment of the M-TES system based on a case study in China. According to the analysis of the design specifications of the heating system, the suitability of matching the M-TES with existing heating systems was analyzed. The results show that the M-TES is appropriate for use with heating systems with a fan-coil unit and under-floor pipe. Containers and operating strategies for the M-TES with different transportation schemes were also designed. The maximum allowed load of the M-TES container is 39t according to the discussion of transportation regulations on the road. The cost and income of the M-TES in the study case were estimated, and the net present value (NPV) and payback period (PBP) were also calculated. The best operating strategy is the use of 2 containers and 4 cycles of container transportation per day, with a PBP of approximately 10years. The M-TES is applicable for middle and small-scale heat users in China.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.