Abstract

Low enthalpy geothermal based Combined Cooling, Heating and Power (CCHP) system for building is expected can increase energy efficiency and reduce carbon dioxide emission. The aim of this study is to assess techno-economic performances of a CCHP for hotel building in tropical countries with total energy demand of 7.64 MW. The fresh geothermal fluid was divided by 15% to power generation system of Organic Rankine Cycle (ORC) and the waste heat merged with the rest fresh geothermal to absorption refrigeration system and heating systems. Cycle Tempo and COMSOL are used to simulate CCHP system and a borehole of hot sedimentary aquifer (HSA), respectively. The simulation results indicate that total CCHP system efficiency is 36.61% consist of ORC efficiency and absorption cycle efficiency are 12.77% and 57.88%, respectively with emission reduction of 1.4 ton CO2 eq. per year compare to conventional grid electricity. The best business scheme was BOO with financial incentives, which were tax allowance, soft loan, and grant. Therefore, the production prices were 0.08 USD/kWth, 0.10 USD/kWeh, and 12.03 USD/MMBtu for cooling, electricity, and heating respectively.

Highlights

  • Regarding to increase energy efficiency, Indonesia has target to reduce 1.7% it in every year commercial sector [1]

  • Despite energy demand in commercial sector for space cooling, lighting, space and water heating are growing significantly, but current energy efficiency implementations are not having a substantial effect in achieving the target

  • The importance of energy efficiency in Indonesia was shown on the escalation of energy demand by 3.99% in 2000 – 2014 [2]

Read more

Summary

Introduction

Regarding to increase energy efficiency, Indonesia has target to reduce 1.7% it in every year commercial sector [1]. Despite energy demand in commercial sector for space cooling, lighting, space and water heating are growing significantly, but current energy efficiency implementations are not having a substantial effect in achieving the target. The importance of energy efficiency in Indonesia was shown on the escalation of energy demand by 3.99% in 2000 – 2014 [2]. Final energy consumption of Indonesian’s commercial building was 5.64% or equal to 38 million BOE in 2016 [3]. Electricity and cooling are the main energy needs for commercial building in tropical countries like Indonesia. The number of hotel building in 2016 up to 2,387 hotels with 233,007 rooms [4]

Objectives
Methods
Results
Conclusion