Abstract
In this paper, effects of the transformer on the EMI performances of the converter system are first discussed. An equivalent circuit of a transformer incorporating the parasitic elements has been carried out to model the important dominant behavior of the high-frequency noise coupling mechanisms. To achieve the noise current balance, the technique of using the noise-reduction winding, to mitigate the common-mode (CM) EMI noise caused by the capacitive CdV/dt displacement current (i.e., caused by the voltage distribution in windings), is then proposed and implemented in the power supply system. It is found that if the induced dV/dt sources and loads are balanced, the electromagnetic energy (i.e., noise) circulates between the noise-sources and loads within the transformer, then so no CM EMI noise goes through LISN resistors, leading to substantially decreased CM EMI. The theory of CM EMI reduction based on the noise current balance technique is presented. Design examples are given in this paper and results are verified by experimental measurements.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.