Abstract
After reduction of a displaced supracondylar humerus fracture, the distal humerus must be easy to visualize; radiographic techniques in which the forearm overlaps the distal humerus make interpretation of fracture reduction difficult. Eighteen patients with displaced supracondylar humerus fractures were treated with reduction that was maintained manually with a variant of Dunlop's extension traction. This allows direct fluoroscopic evaluation of Baumann's angle, the contour of the distal humerus, the pin insertion site, and the angle of pin insertion. In young patients with a thin distal humerus and swollen elbow, the easiest pin placement may be achieved by inserting the pin on the lateral view (after the anteroposterior view confirms a satisfactory reduction).
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.