Abstract

Two techniques are described which correct scattering parameter data taken on an N-port device measured with N-2 imperfect terrniuations and a two-port network analyzer. The first technique rises a simple iterative algorithm and may be easily implemented in software. Each iteration reduces the error due to imperfect terminations typically by one decade. The second, more complicated, technique uses a general closed-form solution which requires specially developed Gamma-R parameters of which S-, Y-, and Z-parameters are particular cases. The closed-form solution is completely valid for any termination. The closed-form solution is the limit to which the iterative solution converges. The iterative technique has been implemented in software controlling an HP 8409 automated microwave network analyzer.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call