Abstract

To evaluate the possibility of lowering radiation dose from a localizer radiograph (LR) using a tin spectral shaping filter and to investigate the effect of this adaptation on the radiation dose and image quality of subsequent computed tomography (CT) examination. The study utilized a set of semianthropomorphic abdomen phantoms, representing small, medium, and large patients. The LR scans were performed with and without a tin spectral shaping filter using various kVp/mA settings. The tube current values of spiral CT examinations following the LR were assessed to evaluate the effect of LR settings on automatic exposure control (AEC). The image quality of CT examinations with various LRs was evaluated by measuring image noise in several regions-of-interest. Organ dose values from LR scans were derived from Monte Carlo simulations performed on a set of virtual anthropomorphic phantoms and the effective dose (ED) values were calculated. The radiation dose from the LR can be strongly reduced by using a tin spectral shaping filter (P<0.001). The optimal settings of the LR scan depend on the size of the scanned subject: for small and medium size subjects, the combination of a tin spectral shaping filter with 100kVp and 20mA resulted in the lowest possible radiation dose (ED=0.007mGy) without compromising the AEC and image quality of subsequent CT. In contrast, the LR settings of 100kVp with a tin spectral shaping filter and the tube current values of 20 and 35mA in large subject (47.4cm in diameter) resulted in significant variation of the TCM values (11.1% and 8.4%, respectively) and the corresponding increase of noise by >5% in subsequent CT examination. For all investigated phantom sizes, the combination of 100Sn kV with a tin spectral shaping filter and tube current values of 75mA results in the lowest possible radiation dose, while still keeping the AEC function unchanged. The study indicated that tin spectral shaping filtration can be applied to LRs for radiation dose reduction, but such adaptation needs to take patient size into account.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.