Abstract

The study focuses on thermal management in tumor-treating fields (TTFields) therapy, crucial for patient compliance and therapeutic effectiveness. TTFields therapy, an established treatment for glioblastoma, involves applying alternating electric fields to the brain. However, managing the thermal effects generated by electrodes is a major challenge, impacting patient comfort and treatment efficiency. This research aims to explore methods for controlling temperature increases during TTFields therapy without reducing its duty cycle. The study emphasizes optimizing electrode configurations and array arrangements to mitigate temperature rise, thereby maintaining therapy effectiveness and patient compliance. Using a simplified multi-layer tissue model and finite element analysis, various electrode configurations and array shapes were tested in COMSOL Multiphysics v6.0. Adjustments included changing the electrode gel layer radius from 8 to 12mm, electrode spacing, and transitioning to a more uniform array arrangement, such as a square array or a circular array. The study revealed a strong correlation between high temperatures and edge current density distributions on electrodes. It was found that increasing the electrode gel layer's diameter, enlarging electrode spacing, and adopting a uniform array arrangement markedly mitigated temperature rises. By increasing the gel layer radius from the original 10 to 12mm, a reduction in the peak temperature increases of approximately 0.3°C was observed. Changing the layout from rectangular to circular with the same area further reduced the peak temperature rise by 0.5°C. Additionally, enlarging the spacing between electrodes also contributed to temperature control. By integrating these strategies, we designed a new circular electrode array with an electrode spacing of 45mm and a gel radius of 12mm, successfully reducing the peak temperature from 42.1°C to 40.8°C, effectively achieving temperature control. The research demonstrates that improving electrode and array configurations can effectively manage temperature in TTFields therapy without compromising treatment duration. This strategy is crucial as TTFields therapy relies on prolonged field exposure for effectiveness. The findings offer valuable insights into thermal management in electrode array design and could lead to enhanced patient compliance and treatment efficacy in TTFields therapy.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call