Abstract

AbstractSubsurface intakes can be used as part of the pretreatment system for seawater reverse osmosis facilities. Wells of various designs and galleries are being used for intakes at many sites globally to reduce pretreatment costs, chemical usage, biofouling potential, and environmental impacts (entrainment and impingement). The goal of using a subsurface intake is to reduce or replace conventional pretreatment processes. A field and laboratory investigation was undertaken to assess the feasibility of developing a seabed gallery intake offshore near the Shoaiba seawater RO (SWRO) plant site (150,000 m3/d treatment capacity) that could be used to replace the current intake used for only the RO capacity. A survey of the beach and offshore area was made and 51 sediment samples were collected from the seabed for laboratory analysis of grain size distribution, porosity, and hydraulic conductivity. Field observations showed that the marine bottom has a low slope from the shoreline seaward a distance of about ...

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.