Abstract

IntroductionTo assess the technical feasibility and safety of repeated percutaneous computed tomography (CT)–guided transthoracic biopsies and intratumoral injections of gene-modified dendritic cells in metastatic NSCLC. MethodsA total of 15 patients with 15 NSCLC lesions measuring greater than 1.0 cm underwent two cycles of intratumoral biopsies and CCL21 dendritic cell injections separated by 7 days. All needle placements and injections were done under CT guidance. Clinical and imaging follow-up was done approximately 4 weeks after the first procedure. Safety and feasibility were determined as: (1) safety and feasibility similar to that of single-needle biopsy, and (2) an absence of serious adverse events defined as grade greater than or equal to three according to the National Cancer Institute Common Terminology Criteria for Adverse Events version 5.0. ResultsA total of 30 percutaneous, transthoracic intratumoral biopsies and injections into the lung cancer were performed, two cycles (at d 0 and 7) received by each patient (311 biopsies and 96 intratumoral injections). All percutaneous cases achieved technical success with respect to needle placement for both biopsy and injection of CCL21 dendritic cells. Only minor complications were observed (grade <3), including pneumothorax (n = 10, 33%) and small postbiopsy hemorrhage (n = 2, 7%). Pneumothorax was moderate (n = 1) or trace (n = 9), with resolution of the moderate pneumothorax after manual aspiration without chest tube placement. No patient required chest tube placement. No other complications or serious adverse effects related to the biopsy or dendritic cell injection were noted. All patients were in stable condition after up to 4 hours in the recovery unit and were discharged home on the same day. No procedure-related complications were observed on imaging or clinical follow-up at 4 weeks. ConclusionsRepeated percutaneous, transthoracic CT-guided biopsies and intratumoral gene-modified cell-based immunotherapy injections into lung cancers are technically feasible, safe, and reproducible. There were no procedure-related serious (defined as grade ≥3) adverse events.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.