Abstract

Modification of JT-60U to a superconducting device (so called JT-60SA) has been planned to contribute to ITER and DEMO. The NBI system is required to inject D 0 beams of 34 MW for 100 s. The upgraded NBI system for JT-60SA consists of 12 positive-ion-based NBI (P-NBI) units and one negative-ion-based NBI (N-NBI) unit. The injection powers of each P-NBI and N-NBI units are 2 MW at 85 keV and 10 MW at 500 keV, respectively. On JT-60U, the long pulse operations of 30 s at 2 MW and 20 s at 3.2 MW have been achieved on the P-NBI and N-NBI units, respectively. Both units have demonstrated no injection power degradation for long pulse operation. It has been also found that the thermal time constants of the main key components with active cooling, such as the ion source of the present NBI system, are less than ∼20 s. Therefore, the pulse extension up to 100 s is expected to need some modifications mainly the power supply system. In addition, the voltage-holding capability of the negative ion source is required to be improved. The detailed technical design of the NBI system for JT-60SA is presented.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.