Abstract

We performed modified aortic root replacement using a composite graft in seven patients over a 7-year-period. Six patients underwent emergency surgery for acute aortic dissection and one patient underwent elective surgery for an aortic aneurysm. To make the composite graft, we chose an artificial valve that was 1 mm larger than the graft, and when performing the proximal anastomosis, we sutured only the graft edge using the horizontal mattress suture technique, applying an additional running suture for reinforcement. The button technique was routinely used for coronary reattachment. To assess hemostasis of the aortic proximal and coronary suture line, cardioplegia was injected via the left atrial vent, which enabled us to confirm hemostasis before performing the distal anastomosis. Blood loss and the need for blood transfusion were minimized by this modified technique. None of the six survivors has required reoperation during 7-year period. Our technique of aortic root replacement based on a composite graft with some operative modifications seems to be safe and reliable, resulting in a satisfactory outcome.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.