Abstract

Diabetic patients are at significant risk of developing corneal lesions such as superficial punctate keratitis, recurrent corneal erosions, persistent epithelial defects, and microbial keratitis. The aim of this study was to investigate whether diabetes mellitus is correlated with both reduced corneal sensation and reduced tear production. In 25 type II diabetic patients with a history of retinopathy only and in 25 nondiabetic control subjects (age and sex matched), we performed noncontact corneal aesthesiometry and assessed basal tear production using Schirmer's test with topical anesthesia. The noncontact corneal aesthesiometer (NCCA) is a new noninvasive device for quantifying threshold corneal sensitivity. The diabetic patients demonstrated a significantly reduced Schirmer's test result (P<.001) and significantly reduced corneal sensitivity (P<.01). Our study supports previous reports of reduced basal tear production, lending more support to the theory of a peripheral neuropathy affecting lacrimal gland function in diabetes. We also confirmed reduced threshold corneal sensitivity in diabetic patients using the NCCA.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.