Abstract

There are a variety of approaches to assess the efficacy of reperfusion therapy, and myocardial protection, in acute myocardial infarction. This review summarizes the available evidence validating the use of technetium-99m sestamibi single-photon emission computed tomography (SPECT) for this purpose. Multiple lines of evidence have validated its clinical utility. SPECT sestamibi infarct size has been used as an endpoint in multiple randomized clinical trials. A smaller number of clinical trials have used both early and later imaging with SPECT sestamibi to assess myocardium at risk and myocardial salvage. SPECT sestamibi has a number of limitations which must be recognized. Nevertheless, SPECT sestamibi infarct size is a well-validated measurement with a long track record of performance as an endpoint in multicenter, randomized clinical trials.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.