Abstract

A collaborative study was conducted on a liquid chromatographic (LC) method for determination of taurine in infant formula and milk powders. Twenty laboratories participated in the analysis of 8 blind duplicates over the range of approximately 3-60 mg/100 g sample. The method involved protein removal, conversion to the dansyl-derivative, and isocratic LC separation with UV and/or fluorescence detection. Following outlier treatment, overall mean RSDR has been estimated at 7.00% for supplemented products with a HORRAT value of 1.1. The poorer precision at endogenous levels establishes a lower limit of determination of about 5 mg/100 g. An overall mean RSDr:RSDR value of 0.7 for all products demonstrated acceptable performance.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.