Abstract

The efficacy of coagulation and membrane filtration was studied for the treatment of boiler-blowdown (BBD) wastewater to enable reuse and minimize the overall water consumption in steam-assisted-gravity-drainage (SAGD), thermally enhanced, oil recovery operations. Direct nanofiltration of chemically unadjusted BBD at its original pH was the optimal treatment option with respect to the flux stability and the removal of dissolved organic material and salinity, which if not removed would result in the fouling and failure of downstream process equipment. The naturally high solute hydrophilicity allowed for prolonged operation with an elevated flux of 60 L m−2 h−1 (LMH) and recovery up to 85% while maintaining solute removal as high as 80% and 45% for dissolved organic carbon and total dissolved solids, respectively. Comparatively, neither precoagulation nor preacidification improved the rejection of dissolved organic material or salinity and consistently resulted in increased membrane surface fouling and flux...

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.