Abstract

Furuno FQ-80 Scientific Echo Sounder can be performed on dual-frequency capabilities, 38 kHz and 120 kHz, as an individually or simultaneously. Measurement of target strength (TS) for Selar boops (Oxeye scad) had been deployed using FQ-80 on 228 dB and 236 dB of source level (SL) at low and high frequency, respectively. The fish were sited in the net cage at the bottom of the vessel. TS value, depth, and position (x-y-z) of single fish which detected at every ping at low and high frequency has been observed from recorded echogram using FQ-80 Analyzer. Fish TS detected at low and high frequency are ranging from -47.40 to -38.33 dB with the average of -44.49 dB and -45.19 to -42.76 dB with the average of -43.96 dB. Thus, fish TS detected at higher frequency is stronger than at lower frequency.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.