Abstract
Specification of the target reliability levels is one of the key issues of the assessment of existing systems. ISO 2394:2015 indicate procedures for specification of the target reliability levels by optimisation of the total cost related to an assumed remaining working life of a structural system. These approaches are critically compared with human safety criteria and with recommendations of present standards. It appears that the requirement on the same target reliability levels for existing civil engineering systems as for newly designed is uneconomical. Decisions in the assessment can result in the acceptance of the actual state or in upgrade of the existing structure, two reliability levels are thus needed - the minimum level below which the structure is unreliable and should be upgraded, and the target level indicating an optimum upgrade strategy. When reliability of a system or its key component is verified (as compared to design of a common component), the target reliability index should be increased by about 0.5.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.