The hardening of instruments to survive NIF target emission environments presents a significant challenge. Neutron flux is predicted to be as much as six orders of magnitude greater than the highest achieved neutron flux on NOVA. Not withstanding the high prompt radiation fields, the specifications for the instruments are demanding requiring high resolution imaging and sub nanosecond transient measurements. The authors present an analysis of the sensitivity of the proposed NIF instrumentation design to EMP, X-rays, gamma rays, and neutrons. Major components assessed include fiber optic cable transport, high bandwidth cable and charge coupled detector (CCD) imaging systems.