Abstract

Removing tantalum (Ta) from nickel-iron (NiFe) surface in CF 4/O 2 plasma was first demonstrated to be a more robust process than argon ion milling in preserving and controlling the NiFe magnetic thickness during Ta overetch. A factorial study showed that the NiFe magnetic thickness loss could be further reduced by replacing CF 4 with CHF 3 and reducing O 2 flow. For an optimized CHF 3/CF 4 process, the NiFe magnetic thickness loss for a 100-Å Ta overetch was only 5 Å. Electron spectroscopy for chemical analysis showed the presence of the fluorocarbon on the CF 4/CHF 3 etched Ta surface and nickel fluoride on the NiFe surface after Ta overetch. A mechanism of removing tantalum with minimum effect on the underlying nickel-iron thin film was also proposed.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.