Abstract

BackgroundMany algorithms have been developed for deciphering the tandem mass spectrometry (MS) data sets. They can be essentially clustered into two classes. The first performs searches on theoretical mass spectrum database, while the second based itself on de novo sequencing from raw mass spectrometry data. It was noted that the quality of mass spectra affects significantly the protein identification processes in both instances. This prompted the authors to explore ways to measure the quality of MS data sets before subjecting them to the protein identification algorithms, thus allowing for more meaningful searches and increased confidence level of proteins identified.ResultsThe proposed method measures the qualities of MS data sets based on the symmetric property of b- and y-ion peaks present in a MS spectrum. Self-convolution on MS data and its time-reversal copy was employed. Due to the symmetric nature of b-ions and y-ions peaks, the self-convolution result of a good spectrum would produce a highest mid point intensity peak. To reduce processing time, self-convolution was achieved using Fast Fourier Transform and its inverse transform, followed by the removal of the "DC" (Direct Current) component and the normalisation of the data set. The quality score was defined as the ratio of the intensity at the mid point to the remaining peaks of the convolution result. The method was validated using both theoretical mass spectra, with various permutations, and several real MS data sets. The results were encouraging, revealing a high percentage of positive prediction rates for spectra with good quality scores.ConclusionWe have demonstrated in this work a method for determining the quality of tandem MS data set. By pre-determining the quality of tandem MS data before subjecting them to protein identification algorithms, spurious protein predictions due to poor tandem MS data are avoided, giving scientists greater confidence in the predicted results. We conclude that the algorithm performs well and could potentially be used as a pre-processing for all mass spectrometry based protein identification tools.

Highlights

  • Many algorithms have been developed for deciphering the tandem mass spectrometry (MS) data sets

  • Quantitative measurement of theoretical tandem MS spectra We first compute the quality score (QS) on theoretical MS spectra based on our derivation shown in Eq 1

  • We conclude that the new approach is effective and useful in assessing the quality of tandem mass spectrum by analysing the self-convolution result of the spectra

Read more

Summary

Introduction

Many algorithms have been developed for deciphering the tandem mass spectrometry (MS) data sets. They can be essentially clustered into two classes. It was noted that the quality of mass spectra affects significantly the protein identification processes in both instances. This prompted the authors to explore ways to measure the quality of MS data sets before subjecting them to the protein identification algorithms, allowing for more meaningful searches and increased confidence level of proteins identified. A mass spectrometer is an instrument used to measure the mass-to-charge ratio of individual molecules that have been converted into electrically charged molecules, or ions [1]. Large amounts of proteomics data are produced and made available to the public [3,4,5]

Methods
Results
Discussion
Conclusion