Abstract
We propose a 5×5 arrayed MEMS planar tactile display device (1 mm pitch) consists of SMA thick film actuator array and photo-lithographed SU8 micro-mechanism of bias spring, micro-pin, and cap array. The SU8 bias spring was designed so that the tactile display can generate 20 μm displacement and 5 mN force when it is combined with the SMA actuator in static motion. The amplitude of the tactile display decreased with increasing driving frequency when it was driven by pulse voltage with 50 % duty ratio. However, the device was able to generate amplitude larger than 10 μm, sufficient for vibratory stimulation to human skin, at 30 Hz with low duty ratio.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.