Abstract
There is still conflicting evidence about the true benefit of minimally invasive (MI) techniques in total hip replacement (THR). The aim of this prospective study was to evaluate the safeness of a MI approach during the learning curve of a single surgeon. Second, clinical and radiographic results among the MI THR group were compared with the results using a standard transgluteal (Bauer) approach. 86 primary unilateral total hip arthroplasties (THAs) through a MI, anterior (Micro-hip(®)) approach were performed by a single senior surgeon (ES), representing a consecutive series of patients after beginning with the MI technique. Cases were compared to a matched cohort of patients who were treated with a standard transgluteal (Bauer) approach. Operation time, incision length, perioperative blood loss, haemoglobin level and blood transfusions were monitored. Complications were documented and followed up 1 year postoperatively. The Harris Hip Score (HHS), range of motion, use of analgetics, the Trendelenburg sign, sensibility of the lateral femoral cutaneous nerve and the acetabular/femoral component placement as well as potential heterotopic ossifications were analysed in both the groups after 12 months postoperatively. 74 MI THR patients and 60 standard THR patients were available for the one year follow-up. Operative time was significantly longer in the MI group, reduction in the haemoglobin level during the first 24 h was significant and the length of skin incision was significantly shorter. No significant differences were found for HHS, range of motion, use of analgetics, the Trendelenburg sign, and the acetabular/femoral component placement, heterotopic ossifications and intra- and postoperative complications. Sensibility of the lateral femoral cutaneous nerve was affected in three patients in the MI group. Radiographic evaluation revealed no component migration, implant subsidence or radiolucency signs in both the groups. Consistent with recent meta-analysis we found reduced blood loss, similar clinical/radiographic outcome and similar complication rates compared to standard THA. Our study shows, that MI THR is a safe procedure during the learning curve of an experienced surgeon.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.