Abstract

In this paper, we describe an apparatus for measuring reaction times and movement times involved in reaching for real objects. Subjects view an object through a liquid crystal window, which serves as a shutter that can be made clear or opaque quickly (10 msec from opaque to clear, 30 msec from clear to opaque). The subject’s hand rests on a microswitch-equipped home key, and the object sits on a force-sensitive platform so that initiation of reach and time of contact with the object can be marked accurately. The apparatus interfaces with an IBM PC/AT through a digital I/O parallel port, so that reaction times and movement times are recorded automatically.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.