Abstract

In studies of phrenic nerve (PN) conduction in amyotrophic lateral sclerosis (ALS) both motor response amplitude and latency have been reported as abnormal. However, correlation with diaphragm motor unit loss, and with diaphragmatic function has not been fully evaluated. We studied 83 patients with ALS, and 21 patients referred with clinically suspected phrenic nerve lesions whose studies were normal. PN responses elicited by percutaneous electrical stimulation in the neck were recorded using superficial electrodes placed at the surface markings of the diaphragm on the chest wall, and a concentric needle electrode inserted into the diaphragmatic costal fibres. Electromyography of diaphragm was performed to analyse motor unit morphology and recruitment. Diaphragm changes were scored as: minor, no fibrillation/sharp-waves (fibs-sw) and mild loss of motor units on activation; moderate, fibs-sw and moderate loss of motor units on activation; severe, fibs-sw and few remaining complex motor units with very increased firing-rate. The 21 controls and 83 ALS patients were matched for age. In controls, the only significant correlation between surface and needle recording was for negative-peak amplitude (p = 0.03). In ALS patients, amplitudes and negative-peak area were highly correlated (p < 0.001), as were PN motor latencies (p = 0.002). Forced vital capacity (FVC) was highly correlated with both amplitude (p < 0.001) and PN latency (p < 0.02), whichever electrode was used. PN amplitude recording with needle electrode was consistent with EMG findings in the diaphragm. In general, patients with peak-to-peak amplitude <1.0 mV (20% percentile of the median value) on needle recording tended to show severe changes on needle EMG of the diaphragm, and those with amplitude ⩾1.0 mV to <1.5 mV (1st IQR of the median value) had moderate changes in diaphragm EMG. Generally, EMG changes in internal intercostal muscles mirrored findings observed in diaphragm. In ALS, PN motor amplitude/area and latency measurements recorded by surface electrodes are highly correlated with needle EMG findings in the diaphragm. CMAP amplitude/area measurements showed high correlation with FVC. In ALS, amplitude/area of the motor PN response, recorded by surface or needle electrodes, correlates with dysfunction of the diaphragm.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.