Abstract

Beam to column connections subjected to loads in the beam minor axis direction are usually considered either as pinned or rigid for both resistance and stiffness checks. However, modern codes contemplate the possibility of semi-rigid and partial strength connections. The Eurocode 3 provides criteria, based on the component method, to characterise such connections. There are unresolved issues regarding three-dimensional connections and connections subjected to out-of-plane effects that need further research. Their behaviour relies mainly on the characterisation of the components acting on the T-stub under out-of-plane bending, and this characterisation is the aim of this paper. An experimental program consisting of five T-stub tests has been carried out and finite element models have been developed. The finite element models have been validated with the experimental results and prove to be an accurate tool for the characterisation of 3D connections. The connection characteristics have been obtained by means of tests and finite element models, and after comparison with the limits provided by the Eurocode 3, it is concluded that all connections under study are indeed semi-rigid and partial strength.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.