Abstract
A 2.4 GHz antenna for an electrically small body-worn sensor node is presented. Usually, unbalanced antennas are used in such applications. Implementing a balanced antenna in a small node deployed on the body is problematic from the points of view of both design and characterisation. A solution using a T-matched dipole integrated in the node housing is presented. Techniques for characterisation both in free space and on the body are described. Besides antenna port impedance and radiation efficiency, radiated power and radiation patterns of the active antenna fed by a transceiver in a fully functional sensor node are measured. The benefits and drawbacks of the chosen antenna design and characterisation techniques are discussed.
Published Version
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.