Abstract
Blood volume and systolic blood pressure (SBP) were measured in 43 preterm infants. Mean (SD) blood volume was 83 (19) ml/kg (range 48-119) and SBP 50 (9) mm Hg (range 34-69), showing a significant overall relationship. Blood volume in infants with SBP > 60 mm Hg (110 (6) ml/kg) was significantly higher than in infants with SBP 40-60 mm Hg (78 (16) ml/kg) and in infants with SBP < 40 mm Hg (75 (10) ml/kg). In conclusion, SBP is of limited value in detecting hypovolaemia in very low birthweight infants.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.