PurposeLittle is known about the three-dimensional (3D) transfer accuracy in maxillary repositioning procedures based on conventionally manufactured dental-mounted wafers. The purpose of the present study was a systematic 3D analysis for wafer-based maxillary positioning in orthognathic surgery. Materials and methodsA total of 92 patients underwent Le Fort I in addition to mandibular bilateral sagittal split osteotomies (BSSO). Alignment of the pre- and postsurgical CBCT data sets allowed measuring maxillary position changes in axial, sagittal and transversal directions. ResultsThe highest achieved absolute transfer inaccuracies were 1.37 mm, ±0.84 in the sagittal direction, followed by 1.15 mm, ±0.69 in the axial, as well as 1.05 mm, ±0.79 in the transversal direction. The largest relative deviations could be found for repositions in the transversal plane (109.4%, ±4.5), followed by the axial (66.2%, ±51.5) and sagittal plane (49.3%, ±2.2). Significant transfer accuracy differences of repositioning procedures in the sagittal direction, mainly advancement procedures, could be detected if performed with (1.75 mm, ±0.90) or without (1.18 mm, ±0.78) additional rotational correction component. No significant differences were found between unidirectional and multidirectional maxillary correction procedures. ConclusionThe present study for the first time delivers systematic 3D accuracy data of wafer-based maxillary positioning procedures, attesting to its feasibility but also further encouraging the search for improvement strategies.