Abstract

The phenomenon of adsorption of several 99mTc-radiopharmaceuticals onto disposable syringes is common knowledge and can reach a level of up to 50%, with the result being inadequate dosing. The resulting underdosing has a substantial influence on the quality of imaging, especially in pediatric patients. Therefore, we aimed to establish a standardized in vitro assessment to investigate the adsorption of several 99mTc-radiopharmaceuticals on various brands of syringes. Methods: The 99mTc-radiopharmaceuticals were prepared according to manufacturer instructions. For the assessment, the disposable syringes (n = 3) were filled to one third of capacity with the 99mTc preparation and incubated for 30 min at room temperature. The syringes were emptied into evacuated vials, and the radioactivity of the syringes was measured before and after they were emptied. Furthermore, the dilution effect of 99mTc preparations was studied. We used 2 different brands of syringes and systematically examined 99mTc-pertechnetate, 99mTc-butedronate, 99mTc-oxidronate, 99mTc-medronate, 99mTc-tetrofosmin, 99mTc-sestamibi, 99mTc(V)-dimercaptosuccinic acid, and 99mTc-succimer. Additionally, 99mTc-succimer was retested with 5 brands of syringes. Results: 99mTc-pertechnetate, 99mTc-phosphonates, and 99mTc(V)-dimercaptosuccinic acid showed no significant adsorption. The measured radioactive retention of 2%-5% was equivalent to the determined dead volume. Using 99mTc-tetrofosmin, we found a slight but significant adsorption of 4%-7%. The 99mTc-sestamibi preparation showed a nonsignificant retention of 3%-5%. However, when the 99mTc-sestamibi was diluted 1:10 with saline, the adsorption rate increased to 9%-13%. 99mTc-succimer displayed different adsorption levels depending on the brand of syringe and the preparation technique. The adsorption of 99mTc-succimer, prepared from kits according to the instructions, did not exceed 15%. The 1:10 saline dilution of a 99mTc-succimer kit preparation, as well as an in-house preparation, demonstrated a radioactive syringe adsorption rate of more than 30%. Conclusion: The results revealed the significance of syringe adsorption of radiopharmaceuticals in the prevention of underdosing. Therefore, a quality assurance assessment is recommended before the introduction of new brands of plastic syringes or routine application of diluted or in-house radiopharmaceuticals.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.