Abstract

The aim of this study is to present system reconfiguration for a doubly fed induction machine (DFIM) after an open-switch fault is detected in its back-to-back converters. The open-switch fault and its detection for the scheme are discussed first. System reconfiguration is applied to operate the DFIM after the fault is detected. A four-switch converter topology with dc-link midpoint connection is selected to reconfigure the system. An existing pulse-width modulation method is investigated and applied to reconfigure the system, but uncontrollable capacitor voltage drift occurs. This study proposes a technique to solve the drift problem and also improve the quality of the dc-link voltage. Its effectiveness is substantiated by both simulation and experiment.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.