Abstract
To compare the performance of oxygen consumption and air separation inerting systems. This paper established the mathematical models of the oxygen consumption inerting system and air separation inerting system by mass conservation and energy conservation formula, and the equal inerting time method is adopted to assess the overall performance of the two systems. The two system performances, such as volume flow, thermal load, thermal power, mass increment, and additional fuel consumption, are compared. The results show that: The volume flow of the oxygen consumption inerting system is only 22.9% of the air separation system because of its internal circulation air injection characteristics. Furthermore, the thermal load of the oxygen consumption inerting system is reduced by 30% compared to the air separation system. The total additional fuel consumption of the oxygen consumption inerting system is reduced by 93.57% compared to the air separation system.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.