Abstract

The conventional decoupling controls of variable-speed doubly fed wind turbines provide minimal support to the regulation of system frequency. The characteristics of doubly fed induction generator (DFIG) wind turbines and conventional power plans are compared, and the contributions of DFIG to system inertial response and frequency regulation are investigated. The influence of auxiliary loop parameters on the inertial response is illustrated. We also introduce a novel algorithm to enhance the participation of DFIG in existing frequency regulation mechanisms. The proposed approach takes advantage of the fast responses associated with DFIGs. The control system consists of four functional modules, namely, frequency control, rotational speed delay recovery, speed protection, and coordination control with conventional generators. The simulation results show that the control strategy has a fast response speed to the transient frequency error, thereby proving that wind farms can participate in system frequency regulation to a certain extent.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.