Abstract

In order to improve the attenuation frequency range of traditional static two-stage H-type hydraulic muffler, a two-stage follow-up hydraulic muffler driven by gear-screw is designed based on PLC. The Muffler can change its structure parameters according to the rotational speed of the hydraulic pump, and attenuate the two pulsation frequencies of the hydraulic pump. Considering the structural parameters and gear transmission of the muffler, the static and dynamic characteristics of the muffler are analyzed systematically, and the stability of the muffler is verified by the case simulation test. The results show that the two-stage follow-up hydraulic muffler based on PLC can attenuate the two pressure pulsation frequencies at the same time, and the operation is stable and the response speed is fast. The two-stage follow-up hydraulic muffler has practical significance and value to provides a way for engineering hydraulic system noise reduction.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.