Abstract

BackgroundAn objective and noninvasive examination of pupil size variability can be used to assess the activity of the autonomous nervous system. We designed a system that enables binocular, fast, and accurate recordings of different types of pupil variabilities, which are synchronous with other biosignals. This type of measurement system is needed to extend the scope of pupillometry applications.MethodsIn the proposed system, the left and right eyes are independently and interchangeably illuminated to generate alternating images, which are successively acquired by a single camera. The system is composed of four functional modules: the image acquisition module, the image processing unit, the light stimulator, and the controller. The proposed image processing algorithm approximates the shape of the pupil using the best-fit ellipse. The user control panel (controller) precisely sets the stimuli parameters and controls the entire measurement procedure.ResultsThe computer-based binocular system records the pupil size during the pupil light reflexes (direct and indirect) and spontaneous pupil size fluctuations, at a sampling rate up to 75 Hz, with a resolution better than 0.02 mm. Our initial laboratory tests confirmed that the new system is fast and precise (system accuracy better than 0.5% and repeatability better than 4%).ConclusionsThe proposed system’s unique geometry and construction, and the method it uses to detect images from each eye, allows us to monitor the right and left eyes using a single camera with no overlap between the images. The system does not require a very experienced operator, because it is relatively simple and easy to use. Importantly, it is comfortable for the subjects. Additionally, the presented system can operate with other bio-measurement systems using a synchronous signal. These system capabilities can expand the scope of pupillometry research applications.

Highlights

  • An objective and noninvasive examination of pupil size variability can be used to assess the activity of the autonomous nervous system

  • Pupil size variability is defined as the mobility of the pupil over time, both spontaneous and forced by external stimuli

  • The size of the pupil is determined by the balance of two antagonistic iris muscles: the sphincter, which reacts to parasympathetic stimuli, and the dilator, which reacts to sympathetic stimuli

Read more

Summary

Introduction

An objective and noninvasive examination of pupil size variability can be used to assess the activity of the autonomous nervous system. We designed a system that enables binocular, fast, and accurate recordings of different types of pupil variabilities, which are synchronous with other biosignals. This type of measurement system is needed to extend the scope of pupillometry applications. Pupillometry refers to the measurement of pupil size and dynamics. It is a noninvasive objective monitoring technique, which is mainly used to evaluate the autonomous nervous system [2,3,4] and as an objective marker of light input from the retina [5].

Objectives
Methods
Discussion
Conclusion
Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.