Abstract
Goal The purpose of the article is to further develop analytical methods for calculating and synthesizing power electronics systems with deep pulse width modulation (PWM). A three-circuit linear electric drive system for positioning the working body of the mechanism of onboard aircraft equipment, in which the linear electric motor is controlled from a pulse width converter (PWC), is considered. The power converter is included in the current loop. It has a noticeable effect on the level of current ripple, travel speed and positioning accuracy of the operating mechanism of a linear electric drive. Methodology. To analyze the processes in the current loop, a discrete transfer function of a pulse-width converter for PWM in the final zone and «in the large» is obtained on the basis of the statistical linearization of the modulation characteristics of the multi-loop PWM model. The modulation characteristic of each circuit of the model is obtained as a result of the Fourier series expansion in Walsh functions of the output voltage of the PWM during the PWM process. Statistical linearization of modulation characteristics is performed based on Hermite polynomials. Results. During the analysis, discrete transfer functions of closed current loops, velocity and open loop position were obtained, for which a digital controller was synthesized in the form of a recursive filter. Originality. The parameters of the regulator links are found, which make it possible to complete the transient process in four PWC switching periods with an overshoot of no more than 6 %. The analysis of the speed-optimized positioning process of a linear electric drive based on the LED AT 605TU motor is carried out. Practical significance. The purpose of the analysis was to establish the relationship between the switching period of the PWM and the value of the uncompensated constant, at which the pulsations of the positioning process are minimal while ensuring the minimum overshoot and maximum speed. It was found that the specified requirements are satisfied by the ratio between the switching period, PWC and uncompensated constant in the range of one or two.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.