Abstract

Copper-64, a positron emitter suitable for positron emission tomography (PET), demonstrates improved in vivo clearance when chelated by the cross-bridged tetraazamacrocycle CB-TE2A compared to TETA. Good in vivo clearance was also observed for 64Cu-CB-TE2A conjugated to a peptide, which converts one coordinating carboxylate pendant arm to an amide. To better understand the in vivo stability of peptide- conjugated CB-TE2A, cross-bridged monoamides were synthesized. Crystal structures of natCu(II)-CB-TEAMA and natCu(II)-CB-PhTEAMA revealed hexadentate, distorted octahedral coordination geometry. In vivo biodistribution showed clearance of all 64Cu-radiolabeled cross-bridged monoamides from liver and bone marrow such that uptake at 24 h was <10% of uptake at 30 min. In contrast, >60% of 30 min uptake from 64Cu-TETA was retained in these tissues at 24 h. Clearance of 64Cu-cross-bridged monoamides from nontarget organs suggests good in vivo stability, thus supporting the use of CB-TE2A as a bifunctional chelator without modifications to the macrocycle backbone.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.