Magnesium has recently received an increased amount of interest due to its potential use in biodegradable implant applications. The rapid degradation of conventional Mg is, however, a major limitation that needs to be addressed in the design of these materials, along with consideration of toxicity in selection of alloying elements. In this study, five alloys in the Mg-xCa-ySr system (x = 0.5-7.0 wt %; y = 0.5-3.5 wt %) were prepared and characterized for their suitability as degradable orthopedic implant materials. The alloys were characterized using optical microscopy, scanning electron microscopy, energy-dispersive X-ray spectroscopy, X-ray diffraction, degradation measurements in Hanks' solution at 37°C, compression testing, and in vitro cytotoxicity testing with a mouse osteoblastic cell line. The results indicate that the Mg-1.0Ca-0.5Sr alloy is the most promising alloy for orthopedic implant applications since it showed the lowest degradation rate in Hanks' solution (0.01 mL cm(-2) h(-1)) along with no significant toxicity to MC3T3-E1 osteoblasts and a compressive strength of 274 ± 4 MPa.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: Journal of Biomedical Materials Research Part B: Applied Biomaterials
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.