Abstract

BackgroundOrthopaedic implants made of cobalt-chromium alloy undergo wear and corrosion that can lead to deposition of cobalt and chromium in vital organs. Elevated cardiac tissue cobalt levels are associated with myocardial injury while chromium is a well-established genotoxin. Though metal composition of tissues surrounding hip implants has been established, few investigators attempted to characterize the metal deposits in systemic tissues of total joint arthroplasty patients. MethodsWe report the first use of micro-X-ray fluorescence coupled with micro-X-ray absorption spectroscopy to probe distribution and chemical form of cobalt, chromium and titanium in postmortem samples of splenic, hepatic and cardiac tissue of patients with metal-on-polyethylene hip implants (n = 5). ResultsMajority of the cobalt was in the 2+ oxidation state, while titanium was present exclusively as titanium dioxide, in either rutile or anatase crystal structure. Chromium was found in a range of forms including a highly oxidised, carcinogenic species (CrV/VI), which has never been identified in human tissue before. ConclusionsCarcinogenic forms of chromium might arise in vital organs of total joint arthroplasty patients. Further studies are warranted with patients with metal-on-metal implants, which tend to have an increased release of cobalt and chromium compared to metal-on-polyethylene hips.