Abstract

This paper addresses the causes of synchronous torques in split phase induction motors. Firstly an analytical model is outlines to describe the processes involved in producing synchronous torques. This involves the consideration of the motor MMFs interacting with the slot permeances. The results from the implementation of the model are given for several different motor designs to calculate the synchronous torques. These highlight the way that the synchronous torque is a function of the MMF and slotting relationships. Measurement of the synchronous torque is not straightforward however a method of assessment is developed in the paper by using a deceleration and other tests. The test results are fully described in the paper and illustrate that even with correct bar/slot combinations and skew, synchronous torques still exist in the machine.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call