Abstract
Employing synchronous optimal pulsewidth modulation (PWM) techniques permits operating the PWM inverter of medium-voltage drives at very low switching frequency. The switching losses of the power semiconductor devices are thus reduced. The benefit is that a given inverter produces higher fundamental power. The optimal pulse patterns are determined by offline calculation, assuming steady-state operation of the drive machine. Dynamic modulation errors and high overcurrents, as a consequence, are therefore encountered when the operating conditions change. To overcome this problem, the harmonic components of the stator flux linkage vector are subjected to closed-loop control. The target trajectory is derived from the respective pulse pattern in use, while the actual stator flux trajectory is estimated. The approach is insensitive to parameter variations. It eliminates excessive transients when the operating conditions change. Experimental results obtained from an industrial 1-MVA 4.16-kV three-level inverter ac drive are presented
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.