Abstract

This article presents a novel methodology for the determination of synchronous machine parameters from the sudden short-circuit (SCC) test. Records of armature and field currents transient behavior are used to evaluate the d-axis equivalent circuit, including the rotor characteristic reactance, and the traditional synchronous machine parameters. The method is based on the evolutionary computer algorithm, the hybrid particle swarm optimization (HPSO). The developed program has been successfully applied into two large salient pole synchronous machines test data.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.