Abstract

In conventional “flow control valve and travel switch” control strategy, relative height difference between multiple cylinders only reach accuracy of centimetre grade, which can’t meet synchronous control accuracy requirements of many engineering. In order to improve multiple cylinders synchronous accuracy of the hydraulic lifting system, this paper takes a hydraulic lifting system as basis, which studies PID closed loop control system using electro-hydraulic proportional valve and high-precision displacement accuracy sensor, and the synchronous accuracy of 4 cylinders hydraulic lifting system is improved to millimetre grade.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.