Abstract

A hardware efficient method and system for estimating the time constant and measuring the current of the output capacitors in digitally controlled switch-mode power supplies is introduced. The estimator emulates the equivalent RC circuit of the output capacitor with a much smaller version, placed in parallel, and adjusts its own resistance until the two circuits have the same time constant. The adjustment is based on a novel zero voltage crossing detection method and on synchronization with the digital pulse-width modulator operation. The effectiveness of the new estimator is verified with a 5 V to 1 V/5 A, 500-kHz buck converter prototype utilizing an optimal response controller. The experimental results show accuracy within a few tens of nanoseconds in the detection of capacitor zero-current crossing points, corresponding to a smaller than a 1.5% error in the time constant estimation, and, compared to an imperfectly tuned system, about 40% smaller voltage deviation during transients.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.