In this paper, we describe a novel waveguide surface plasmon resonance sensing structure, which consists of a symmetric structure and a planar waveguide. The core component is the symmetric structure of the metal layer, tested sample, and metal layer. The refractive index matching condition of this structure can be adjusted through the thickness of the sample. The planar waveguide is used to excite the surface plasmon wave, and then the parameters are tested and analyzed. The surface plasmon wave is excited when glycerin solutions with concentrations of 0%–70% are used to detect at thicknesses of 300 and 500nm. The problem that the effective refractive index of the ion exchange planar waveguide is large and using this index to excite the surface plasmon wave between the metal and dielectric for detection is difficult to achieve can be countered by appropriately choosing the thickness of the dielectric in order to be able to measure different refractive indices.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.