Abstract

Switching phenomenon of the bathtub vortex in a double-orifice water tank is experimentally investigated. This alternation between “vortexflow” and “nonvortex flow” is caused by flow rate differences through the two orifices. The oscillation frequency is experimentally examined by changing the design parameters, such as the orifice size, the distance between two orifices, and the fluid level. A linear relationship is obtained between the frequency and the flow rate difference.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.