Abstract
This study aimed to transfer a high shear granulation (HSG) process to a twin-screw granulation (TSG) process while maintaining equivalent dissolution profiles. Ibuprofen (IBP) was used as poorly soluble model drug. Granules were obtained by HSG or TSG according to a full factorial design. The liquid-to-solid ratio and wet massing time (HSG) or powder throughput (TSG) were selected as factors. The granules were compressed to tablets with immediate release and a drug load of 50% (w/w). Quality attributes (QAs) of the granules, especially the granule strength (GS), and the resulting tablets were evaluated. The effect of process parameters on the QAs was statistically analyzed. The comparison of HSG tablets with TSG tablets revealed that TSG tablets showed higher tensile strength and lower ejection force than HSG tablets. The dissolution profiles of the tablets in different pH media were also evaluated. Equivalent dissolution profiles in all four media (e.g., f2 values≥54 in pH5.5) were obtained by adjusting process parameters. It was concluded that the GS was the most important QA for dissolution.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.